Adhesive Egg Shape Acoustic Foam/Soundproofing Foam
produce information:Acoustic Foamis self-extinguishing and offers excellent sound absorbing qualities over a wide range of frequencies;It is easy to handle cut and install; The product is available with a wide range of functional or decorative facings and fabrics.
1.Specifications:
Great design for low frequency sound absorption
Best Fire- retardantShapes by demand
2.Features
Absorb sound, keep warm, heat insulation,good elasticity ,walldecoration,shockproof,moistureproof,against friction.
3.Usage
Can be used in residence,redcording studios and home theatresschools, hosipital ,
environmental protection, automotive, Marine, architectural decoration, household appliance;etc.
4.Advantage
1)our factory directly sell with 13 years’ experience
2).resonable noise reduction
3).factory directly sell,with high quality and competitive price,using encironmental material,no toxin.4).test:SGS,BS5852,CA117,ISO9001
Frequency Absorption coefficient
125HZ 0.11
200HZ0.24
400HZ0.64
800HZ 1.06
1600HZ 1.03
40000HZ 1
Description
Studio acoustic paint sound absorb foam, car sound insulation foam, auditorium floor sound insulation foam
Density
25-80kg/ m³
Dimensions
Customized
Max: 2mx1mx0.02/0.09m
CompositionColor Availability
Per customer's requirementCharacteristicsEconomical.Soundproofing.Good drainage.Eco- Friendly, Non Toxin, odor free.Recyclable.Melting Degrees: 250°.Widely used as sound absorber in the Studio, Karaoke, Night Club, etc.
(Other Color & Hardness available)
Manufacturer
Mylon
Property Value Metric (Imperial) Test Method
Density (Core)29 kg/m3 (1.8 lb/ft3) ASTM D1622
Compressive Strength186 kPa (27.0 psi) ASTM D1621
Tensile Strength241 kPa (35.0 psi) ASTM D1623
Open Cell Content8.0% ASTM D2856
Water Absorption1.2 % by volume ASTM D2842
Water Vapour Permeance
50mm sample42 ng/Pa·s·m2 (0.70 Perms) ASTM E96
Dimensional Stability
Volume Change (%) after 28 days
-0.0 @ -20°C (-29°F)
1.5 @ 70°C (158°F) @ 97± 3% RH
0.4 @ 80°C (176°F)
ASTM D2126
Flame Spread Classification**Flame Spread <500
Smoke Developed <500
CAN/ULC-S102
Including S127
Time to Occupancy***24 Hours CAN/ULC-S774
Initial Thermal Resistance (50 mm)RSI: 2.45 m2·K/W (R: 13.9 ft2·hr·°F / BTU) ASTM C518
Hot-Surface PerformancePassed when exposed to 93°C for 96 hours ASTM C 411
Fungi ResistanceAfter 28 day incubation - no fungal growth exhibited ASTM C1338
Mylon factory
Mylon SGS test