Hospital ambulance transport portable medical ICU ventilator machine
Product Description
Display 10.4'' LCD DisplayMode:pneumatically powered and electrically controlled systemTrolley:
Fitted with 4 nos anti-static rubber castors; two of which
are lockable for braking and easy maneuverability with foot operated brake provisionsTechnical Specifications:Gas requirement: Medical oxygen and nitrous oxide with a pressure ranging from 280~600kpasafety valve <12.5 kPaRespiratory Rate1 ~ 99 bpmOxygen Concentration21% ~ 100% Maximum Minute ventilation≥18L / minmodes of ventilationA/C, IPPV, SIPPV, IMV, SIMV, PEET. MANUAL, SIGH, SPONTVentilator compliance≤30 Ml/kPaPEEP:0 ~ 1.0 kPaPtr: -10 ~ 10 hPaIMV frequency:1~20 bpmI/E Ratio:4:1~1:4, Has the inverse ratio ventilationTidal Volume
Setting Range: 50~1500ML
Display Range: 0~2000ml ; resolution ratio: 10mlInspiratory Plateau:0~1sMaximum Safety Pressure≤ 6.0kPaSigh:
one deep breath per 80 controlled respirations,
the inspiration time is 1.5 times of the setting pointPressure limit range:1.0~ 6.0kPa
Airway pressure alarm: Audible and visual and
with yellow and red color indicatingLower: 0.1 kPa ~ 6.0 kPa;Upper: 0 ~ 5.0 kPa±0.2 kPaVentilation Volume alarm: ≥ 18L/ MIN Power Supply AlarmAc/dc power supply are after failing to send out alarm immediately
Alarm Time: keep >120s Operating conditionsAmbient temperature: 10 ~ 40oCRelative humidity:no higher than 80 %Atmospheric pressure:860 hPa ~ 1060 hPaPower requirement: 100-120 Vac, 50/60 Hz;
Attention: the AC power supply used for the anesthesia
machine must be wellgrounded. StorageAmbient temperature: -15oC ~ +50oCRelative humidity: no higher than 95 %Atmospheric pressure: 86 kPa ~ 106 kPa. It should be stored in a room without corrosive gas and well ventilatedPackagepackaging boxcomply with the requirement of GB/T 15464
Between the packaging box and product, soft material
with appropriate thickness provided to prevent loosening
and mutual friction during transportation
Moisture protection and rain protection to ensure that
product is protected from natural damage. Safty & AlarmGas source pressureImmediate alarm; “high level alarm” indicator flickers raising an audible alarm.Airway Pressure Alarm
The airway pressure exceeds 15hpa. The maximum
delay is no longer than 17s. The “high level alarm” indicator flickers raising an audible alarm. Tidal Volume AlarmLower than 50ml, The alarm will be raised after one breathing cycle. Ventilation Volume AlarmLower: 0~12L/Min;Up: 18L/ MinBattery Voltage AlarmIt alrms when the battery voltage is lower than 10.5V.Power On Self TestSelf test before working, assure it's working normally.
Products Show
Hospital ambulance transport portable medical ICU ventilator machine
Packaging & Shipping
Hospital ambulance transport portable medical ICU ventilator machine
Our Services
Hospital ambulance transport portable medical ICU ventilator machine
Company Information
Hospital ambulance transport portable medical ICU ventilator machine
FAQ
Hospital ambulance transport portable medical ICU ventilator machine